Products

Products

What we do

Solved: Saturated liquid water is heated in a steady-flow steam

according to your needs and conditions of use, we will provide energy saving and reliable boiler system solutions.
Let your boiler operate more efficiently and economically

DHL Coal-Fired Steam Boiler

DHL Coal-Fired Steam Boiler

The corner tube boiler uses a piping system as the skeleton of the entire boiler, and it bears the full load of the boiler, which makes a non-framework boiler.

DHL Coal-Fired Hot Water Boiler

DHL Coal-Fired Hot Water Boiler

The corner tube boiler uses a piping system as the skeleton of the entire boiler, and it bears the full load of the boiler, which makes a non-framework boiler. At the same time, this skeleton also serves as the down tube of the boiler and upper and lower headers.

DHX CFB Hot Water Boilers

DHX CFB Hot Water Boilers

As a new mature high-efficiency and low-pollution clean coal technology, circulating fluidized bed combustion (CFBC) technology has many advantages that other combustion methods do not have.

SHL Double Drums Bulk Chain Grate Steam Boiler

SHL Double Drums Bulk Chain Grate Steam Boiler

Series of SHL boiler is bulk industrial boiler with dual boiler cylinders and transverse arranged. The boiler’s hearth consists of front, rear, left and right water wall, the body consists of an upper, a lower drum and convection pipes.

DZL Coal-Fired Steam Boiler

DZL Coal-Fired Steam Boiler

The boiler body is vertical single drum, and the threaded pyrotechnic tube is arranged in the drum to form a convection heating surface, and the drum and the water walls on both sides constitute a radiation heating surface of the furnace.

DZL Coal-Fired Hot Water Boiler

DZL Coal-Fired Hot Water Boiler

DZL series package boiler is a horizontal three-pass water and fire pipe chain grate boiler, which uses medium-sized bituminous coal.

SZL Coal-Fired Steam Boiler

SZL Coal-Fired Steam Boiler

SZL series vertical dual drums chain grate water pipe steam and hot water boiler, adopts quick fitting and assembly structure. The 4-6t/h boiler is of quick fitting pipe structure, exit shop after completely assembled, the boiler of 6-35t/h is composed of 2 main components.

SZL Coal-Fired Hot Water Boiler

SZL Coal-Fired Hot Water Boiler

SZL series vertical dual drums chain grate water pipe steam and hot water boiler, adopts quick fitting and assembly structure. The 4-6t/h boiler is of quick fitting pipe structure, exit shop after completely assembled, the boiler of 6-35t/h is composed of 2 main components.

SHX series CFB steam boiler

SHX series CFB steam boiler

CFB is a low-temperature combustion, so the helium oxide is far lower than the pulverized coal furnace, only 200ppm approximately. At the same time, it is feasible to actualize direct desulfurizing during combustion, and it has high desulfurization efficiency.

SHX series CFB hot water boiler

SHX series CFB hot water boiler

CFBC technology, as a new type and matured high efficient, low-pollution and clean coal technology, it has many advantages that other combustion methods do not have.

Got a question? Call us on +86 13506151129

Or get a quote today

Solved: Saturated liquid water is heated in a steady-flow steam

Solved: Saturated liquid water is heated in a steady-flow Saturated liquid water is heated in a steady-flow steam boiler at a constant pressure of 5 MPa at a rate of 10 kg/s to an outlet temperature of 350C. Determine the rate of heat transfer in the boiler.(Solved) - Saturated steam at 300C is used to heat a Saturated steam at 300C is used to heat a counter currently flowing stream of methanol vapor from 65C to 260C in an adiabatic heat exchanger. The flow rate of the methanol is 5500 standard liters per minute, and the steam condenses and Leaves the heat exchanger as liquid water at 90C.

Solved Problem 4.2 (alternate) - Steam Power Plant Open If the steam leaves the condenser as saturated liquid at 40C, determine the required minimum volumetric flow rate of the cooling water [18.1 cubic meters/minute]. Note that it is always a good idea to validate ones calculations by evaluating the thermal efficiency using only the heat supplied to the steam generator and that rejected by the

[Solved] Repeat Prob. 10-3 for a heat rejection pressure Repeat Prob. 10-3 for a heat rejection pressure of 10 kPa. Prob. 10-3 A steady-flow Carnot cycle uses water as the working fluid. Water changes from saturated liquid to saturated vapor as heat is transferred to it from a source at 250C.Example of Rankine Cycle Problem with SolutionExample of Rankine Cycle Problem with Solution Let assume the Rankine cycle , which is the one of most common thermodynamic cycles in thermal power plants. In this case assume a simple cycle without reheat and without with condensing steam turbine running on saturated steam (dry steam).SOLUTIONS: HOMEWORK 6 - University of Colorado Boulder5-106 Feedwater is heated in a chamber by mixing it with superheated steam. If the mixture is saturated liquid, the ratio of the mass flow rates of the feedwater and the superheated vapor is to be determined. Assumptions 1 This is a steady-flow process since there is no change with time. 2 Kinetic and potential energy changes are negligible.

Saturated Steam vs. Superheated Steam - Burling ValveSaturated Steam vs. Superheated Steam. July 14, 2017 The basics behind steam are simple: when water is heated, it will be vaporized into steam. During this vaporization process, the steam changes from a liquid phase into a gas phase that can be used and controlled in many industrial processes. That means that once the steam is heated Saturated liquid water is heated in a steady-flow steam Saturated liquid water is heated in a steady-flow steam boiler at a constant pressure of 2 MPa at a rate of 4 kg/s to an outlet temperature of 250C. Determine the rate of heat transfer in the boiler.Chapter 44-29 Chapter 4 Example 4.4-36. Steam enters the condenser of a vapor power plant at 0.1 bar with a quality of 0.95 and condensate exits at 0.1 bar and 45oC. Cooling water enters the condenser in a separate stream as a liquid at 20oC and exits as a liquid at 35oC with no change in pressure.Heat transfer

7 58 An adiabatic pump is to be used to compress saturated 758 An adiabatic pump is to be used to compress saturated liquid water at 10 kPa to a pressure to 15 MPa in a reversible manner. Determine the work input using (a) entropy data from the compressed liquid table, (b) inlet specific volume and pressure values, (c) average specific volume and pressure values.